Hyperacute Stromal Transplant Reaction | |
Dense infiltration of the transplant only, no hypopyon (in contrast to an absess). Transplant has to be exchanged. | |
Naumann, G.O.H., Prof. Dr. med., Univ.-Augenklinik, Erlangen, Germany | |
T86.81 | |
Cornea -> Surgical Procedures and Postoperative Findings -> Complications -> Graft Reaction | |